TWO PAIRS OF 3 FOOT LONG LOW LOSS SHIELDED CABLES ARE
SUPPLIED WITH THE Ml 3. USE THESE CABLES TO CONNECT THE
Ml 3 TO A TUNER FOR MULTIPATH RECEPTION. A PAIR OF 6
FOOT LONG SHIELDED CABLES ARE SUPPLIED FOR CONNECTING
THE Ml 3 IN AUDIO CIRCUITS.
CONNECTING TO MclNTOSH MR 71 OR MR 67 TUNER.
Connect a 3 foot low loss shielded cable from the TP No. 1 (Test Point
No. 1 jack on top of the tuner chassis) to the Signal Strength (vertical)
Input on the Ml 3.
Connect a second 3 foot low loss shielded cable from the TP No. 2
(Test Point No. 2 jack on rear of the tuner chassis) to the deviation
(horizontal) Input on the Ml 3.
cable to the tuner chassis ground. Use one of the 1 foot long low-loss
shielded cables, stripped and tinned on one end (female jacks on the
other end) supplied with the Ml 3.
Use a connector with male plugs to connect the soldered - in cable from
the tuner to the Deviation (horizontal) Input on the Ml 3. Connect a 3 foot
low-loss shielded cable from the test point (on top of tuner chassis) to the
Signal Strength (vertical) Input on the Ml 3.
CONNECTING TO MclNTOSH MR 65B TUNER.
Remove capacitor C 27 (.005 MFD) connected between TP No. 1 and
chassis ground. MR 65B tuners, serial numbers 300UO and above, do not
have this capacitor.
Connect a 3 foot low-loss shielded cable from the MR 65B TP No. 1 (Test
Point No. 1 on tuner back panel) to the Signal Strength (vertical) Input
on the Ml 3.
Connect a 3 foot long low-loss shielded cable from the MR65B TP No. 2
(Test Point No. 2 on rear of tuner chassis) to the Deviation (horizontal)
Input on the Ml 3.
CONNECTING TO MclNTOSH MX 110 TUNER-PREAMPLIFIER
WITH Z OR X SERIAL NUMBERS
Connect a 3 foot low loss shielded cable from the MX 1 1 0 TP No. 1
(Test Point No. 1 jack on top of the tuner chassis) to the Signal Strength
(vertical) Input on the Ml 3.
Connect a second 3 foot low-loss shielded cable from the MX 110 TP
No. 2 (Test Point No. 2 jack on top of the tuner chassis) to the Deviation
(horizontal) Input on the Ml 3.
CONNECTING TO MclNTOSH MX 110 TUNER-PREAMPLIFIER
WITH M SERIAL NUMBERS
Remove capacitor C 1 30 (.005 MF) connected between the test point
and ground.
Solder the center lead of a 1 foot low-loss shielded cable to the junction
point of R 139 (10K) and C 125 (.1 MFD). Solder the outer shield of the
CONNECTING TO MclNTOSH MR 65 AND 65A
Remove capacitor C 31 (.005 MFD) connected between the test point
and ground.
Connect a 3 foot low-loss shielded cable from the MR 65A Test Point
(jack on top of tuner chassis) to the Signal Strength (vertical) Input on
the Ml 3.
Connect a 3 foot low-loss shielded cable from the MR 65A MPX out jack
on the tuner back panel to the Deviation (horizontal) Input on the Ml 3.
If an external multiplex adapter is being used with the MR 65 a "Y"
connector will be needed in the MPX output jack. This allows both the
MPX adapter and the lead to the Ml 3 to be connected.
CONNECTING TO MclNTOSH MR 66 TUNER
Remove capacitor C 1 25 (.005 MFD) connected between the test point
and ground.
7