FM ALIGNMENT
ADJUST
Top (secondary)
and bottom
(primary) of
T1.T2, T3
Primary and
secondary of
T4
Secondary
(top)
of
T-5
-4
L-4
C-2,
C-3
L-1, L-2,
L3
Primary (bottom)
of T-5
L-2,
C-3
Muting threshold
control
TEST
LIMITS
Maximum pos-
sible negative
voltage
Maximum pos-
sible negative
voltage (should
be 20 to 30
volts)
Adjust for 0 volts
Maximum nega-
tive voltage
SAME
SAME
SAME
0.5% distortion
or less
Minimum tilt
IHFM Sensitivity
2.5 microvolts
for 3% total
noise and
distortion
REMARKS
Before making any adjustments, set the controls as follows:
a) Input selector switch to FM mono,
b) Volume control maximum CCW.
c) Muting pot maximum CW.
d) Muting OUT.
e) Stereo light adjust maximum CW.
Shunt to ground the winding not being adjusted. Do this with a .01
MFD capacitor in series with a 1K resistor. Attenuate signal generator
until output voltage at TP#1 is less than 1.5 volts with one IF trans-
former winding shunted. IF transformers have terminal #1 marked
with a green dot and are numbered clockwise.
_
Muting pot. MUST be maximum CW.
The primary (bottom) of T-5 should be adjusted only if a distortion
analyzer is available.
Repeat steps 4 and 5 until dial calibration is accurate.
As output increases, attenuate signal generator to keep maximum out-
put at TP#1 to less than 1 volt.
Repeat steps 6 and 7 until output is as high as possible.
Use a strong signal from the FM generator. Adjust T-5 primary for
minimum distortion. IF A DISTORTION ANALYZER IS NOT AVAILABLE,
OMIT THIS STEP. DO NOT ADJUST T-5 PRIMARY.
Observe direction of tilt of overall response curve at 105MC and 90MC.
If
direction
is the
same,
adjust
L-2 at
100MC
for
minimum
tilt.
Re-check
tilt
at
90MC
and
105MC.
If
direction
is not the
same, adjust
L-2 (at
90MC)
and L-3 (at
105MC)
for
minimum
tilt.
Check
tilt
again
at
100MC.
With FM generator set for 2.5 microvolts output, place muting control
to "IN." Adjust the muting threshold control to the point at which the
sine wave on the scope becomes erratic.
Step 11 is an overall sensitivity check. It requires a distortion analyzer
and FM signal generator with attenuator. With 2.5 microvolts input at
the 300 ohm terminals, TP#1 voltage should be .45 volts or more.